47127 Picture of product Schneider Electric

View all Masterpact NT

Masterpact NT - 47127

Configured references

47127 Picture of product Schneider Electric
View all Masterpact NT
Masterpact NT - 47127
Configured references

circuit breaker Masterpact NT08L1 - 800 A - 4 poles - fixed - w/o trip unit

Show more characteristics >
Add to My Products Add to My Products

  • Main
    range of product
    Masterpact NT
    product or component type
    Basic frame
    device short name
    Masterpact NT08
    circuit breaker name
    Masterpact NT08L1
    poles description
    4P
    neutral position
    Left
    network type
    AC
    breaking capacity code
    L1
    suitability for isolation
    Yes conforming to IEC 60947-2
    utilisation category
    Category A
    Complementary
    network frequency
    50/60 Hz
    control type
    Push-button
    mounting mode
    Fixed
    [In] rated current
    800 A ( 40 °C )
    [Ui] rated insulation voltage
    1000 V AC 50/60 Hz conforming to IEC 60947-2
    [Uimp] rated impulse withstand voltage
    12 kV conforming to IEC 60947-2
    [Icm] rated short-circuit making capacity
    220 kA 525 V AC 50/60 Hz
    286 kA 440 V AC 50/60 Hz
    330 kA 220/415 V AC 50/60 Hz
    52 kA 690 V AC 50/60 Hz
    [Ue] rated operational voltage
    690 V AC 50/60 Hz conforming to IEC 60947-2
    circuit breaker CT rating
    800 A
    breaking capacity
    100 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
    130 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
    25 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
    150 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
    150 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
    [Ics] rated service breaking capacity
    Ics 100 kA 525 V AC 50/60 Hz conforming to IEC 60947-2
    Ics 130 kA 440 V AC 50/60 Hz conforming to IEC 60947-2
    Ics 150 kA 220/415 V AC 50/60 Hz conforming to IEC 60947-2
    Ics 25 kA 690 V AC 50/60 Hz conforming to IEC 60947-2
    protection type
    Without protection
    mechanical durability
    12500 cycles without maintenance conforming to IEC 60947-2
    electrical durability
    AC-23A : 3000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
    AC-23A : 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
    AC-3 : 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
    2000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
    3000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
    connection pitch
    70 mm
    [Icw] rated short-time withstand current
    10 kA ( 0.5 s ) conforming to IEC 60947-2
    integral instant protection
    7.2...8.8 kA
    maximum breaking time
    9 ms
    closing response time
    < 50 ms
    height
    301 mm
    width
    346 mm
    depth
    196 mm
    Environment
    standards
    IEC 60947-2
    product certifications
    ASEFA
    LCIE
    pollution degree
    3 conforming to IEC 60664-1
    ambient air temperature for operation
    -25...70 °C
    ambient air temperature for storage
    -40...85 °C
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    • Portuguese
    • Russian
    • French
    • Italian
    • German
    • Chinese
    User guide
    Date
    Size
    Add to My Documents
    User manual Masterpact NT06-16 IEC (Version 06)
    Guide d'exploitation Masterpact NT06-16 CEI (Version 07)
    CAD
    Date
    Size
    Add to My Documents
    Basic circuit breaker Masterpact NT06 to NT16 4P; fixed (Version 1.0)
    NT 08 N 4P BASIC FRAME FIXED (Version 1.0)
    Date 9/10/13
    Size 534.7 KB
    Date 9/10/13
    Size 388.9 KB
    Instruction sheet
    Date
    Size
    Add to My Documents
    Fixed and drawout circuit breaker - Masterpact NT (Version 12)
    Manual del usuario Masterpact NT06-16 CEI (Version 01)
    End of Life Information
    Date
    Size
    Add to My Documents
    End-of-Life Instructions Masterpact NT (Version 2.0)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.